{"title":"Siemens Industrial PCs (6AG)","description":"\u003cp\u003eShop Siemens Industrial PCs (6AG) from PLC Department. Networking \u0026amp; Communication.\u003c\/p\u003e","products":[{"product_id":"6fc5253-7bx10-6ag0","title":"6FC5253-7BX10-6AG0 Siemens","description":"\u003cdiv class=\"pd-premium\"\u003e\n\u003cdiv class=\"pd-desc-cols\"\u003e\n\u003cdiv class=\"pd-overview\"\u003e\n\u003ch3 class=\"pd-h\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6FC5253-7BX10-6AG0 is HMI-Advanced software for SINUMERIK 840D\/840DI\/840D sl controls, intended for installation on PCU (operator panel unit). It delivers version 7.6 SP2 HF7 of the HMI, multilingual (German, English, French, Italian, Spanish, Simplified Chinese) on DVD with a standard (single) license. It facilitates enhanced HMI functionality in CNC control systems and machine tool environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-suited\"\u003e\n\u003ch3 class=\"pd-h\"\u003eBest Suited For\u003c\/h3\u003e\n\u003cul class=\"pd-checks\"\u003e\n\u003cli\u003eSINUMERIK 840D\/840DI\/840D sl CNC systems\u003c\/li\u003e\n\u003cli\u003eMachine tool operator panels (PCU-based HMI)\u003c\/li\u003e\n\u003cli\u003eApplications needing multilingual HMI-Advanced interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance\"\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSoftware version\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e7.6 SP2 HF7\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSupported languages\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eDEU, ENG, FRA, ITA, ESP, CHS\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eDelivery medium\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eDVD\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eLicense type\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eSingle (standard) license\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Surplus - Tested (With Warranty)","offer_id":48318753308886,"sku":"6FC5253-7BX10-6AG0","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New \/ Open-Box Surplus","offer_id":48375772512470,"sku":null,"price":3297.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/4912\/0470\/files\/2b2e0441ee174ca231710bfd6d567dfc.jpg?v=1781503958"},{"product_id":"6ag1331-7kf02-2ab0","title":"6AG1331-7KF02-2AB0 Siemens","description":"\u003cdiv class=\"pd-premium\"\u003e\n\u003cdiv class=\"pd-desc-cols\"\u003e\n\u003cdiv class=\"pd-overview\"\u003e\n\u003ch3 class=\"pd-h\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Siemens module 6AG1331-7KF02-2AB0 is a SIPLUS S7-300 SM 331 analog input replacement module (spare part) with conformal coating, compatible with 20-pole backplane connectors. It provides eight isolated analog inputs supporting voltage, current, thermocouple, and resistance measurement, with integrated diagnostics and alarm functions. Based on the discontinued 6ES7331-7KF02-0AB0, this module is used to bridge legacy systems, particularly in environments requiring extended temperature range or harsh conditions, retaining compatibility within S7-300 automation racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-suited\"\u003e\n\u003ch3 class=\"pd-h\"\u003eBest Suited For\u003c\/h3\u003e\n\u003cul class=\"pd-checks\"\u003e\n\u003cli\u003eS7-300 retrofit or maintenance in harsh environments\u003c\/li\u003e\n\u003cli\u003eAnalog signal processing (U\/I\/thermocouple\/resistance)\u003c\/li\u003e\n\u003cli\u003eUse in railway or ruggedized applications\u003c\/li\u003e\n\u003cli\u003eReplacement in conformal-coated SIPLUS systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance\"\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eAnalog inputs\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e8 isolated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSupported signal types\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eVoltage, current, thermocouple, resistance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e9\/12\/14 bit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003ePower consumption (typ.)\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e1 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eOperating temp. range\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e-25 … +70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"pd-h pd-specs-h\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"pd-spec-grid\"\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eI\/O \u0026amp; Electrical\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eNumber of analog inputs\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e8\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSignal types supported\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eVoltage, current, thermocouple, resistance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eResolution\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e9\/12\/14 bit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePermissible input voltage (continuous)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e20 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePermissible input voltage (1 s)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e75 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePermissible input current (destruction limit)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e40 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eConstant measurement current (resistance)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1.67 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eCommunication \u0026amp; Power\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSupply voltage (DC)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e24 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eReverse-polarity protection\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eInput current from L+ (no load)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e200 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eInput current from backplane bus 5 V\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e50 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePower dissipation (typ.)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e-25 … +70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eConnector type\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e20-pole remove\/insert via backplane bus\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e0.289 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePackage dimensions\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e15.00 × 13.00 × 4.80 cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Surplus - Tested (With Warranty)","offer_id":48318329356502,"sku":"6AG1331-7KF02-2AB0","price":420.75,"currency_code":"USD","in_stock":true},{"title":"New \/ Open-Box Surplus","offer_id":48375924621526,"sku":null,"price":2707.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/4912\/0470\/files\/56e4b4e9c1ec81f3d057f52d48607711.jpg?v=1781498230"},{"product_id":"6es7193-6ag20-0aa0","title":"6ES7193-6AG20-0AA0 Siemens","description":"\u003cdiv class=\"pd-premium\"\u003e\n\u003cdiv class=\"pd-desc-cols\"\u003e\n\u003cdiv class=\"pd-overview\"\u003e\n\u003ch3 class=\"pd-h\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7193-6AG20-0AA0 SIMATIC BusAdapter BA LC\/RJ45 is a media-converter module in the ET 200SP distributed I\/O platform. It provides one PROFINET IO interface with built-in two-port switch capability (one RJ45 copper and one LC fiber port), enabling copper-to-fiber network extension. The adapter is used to link ET 200SP modules to PROFINET networks via copper or multimode fiber. Typical applications include industrial control cabinets requiring mixed-media network redundancy or long-distance connectivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-suited\"\u003e\n\u003ch3 class=\"pd-h\"\u003eBest Suited For\u003c\/h3\u003e\n\u003cul class=\"pd-checks\"\u003e\n\u003cli\u003ePROFINET network extension beyond copper limits (up to 3 km)\u003c\/li\u003e\n\u003cli\u003eMixed copper and fiber backbone installations\u003c\/li\u003e\n\u003cli\u003eModular ET 200SP configurations in harsh environments\u003c\/li\u003e\n\u003cli\u003eControl systems with distributed I\/O islands needing media conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance\"\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eInterfaces (switch)\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eRJ45 + LC fiber\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eFiber link distance\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eup to 3 km (50\/125 µm or 62.5\/125 µm)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eCopper link distance\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e100 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eOperating temp.\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e-30 °C … 60 °C (horizontal)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e32 g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"pd-h pd-specs-h\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"pd-spec-grid\"\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eI\/O \u0026amp; Electrical\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eCopper link max length\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e100 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eFiber link max length (50\/125 µm)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e3 km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eFiber link max length (62.5\/125 µm)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e3 km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eFiber wavelength\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1270 … 1380 nm (100BASE-FX)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eCommunication \u0026amp; Power\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePROFINET ports\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1 interface (2-port switch: 1× RJ45, 1× LC)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eDimensions W×H×D\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e20 mm × 69.5 mm × 59 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e32 g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eAmbient temp. (horizontal)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e-30 °C … 60 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eAmbient temp. (vertical)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e-30 °C … 50 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eMax installation altitude\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e5 000 m (see ET 200SP manual for \u0026gt; 2 000 m)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Surplus - Tested (With Warranty)","offer_id":48318321262806,"sku":"6ES7193-6AG20-0AA0","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New \/ Open-Box Surplus","offer_id":48375930519766,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/4912\/0470\/files\/76a467191a8e19299f55373ae0e76ca9.jpg?v=1781498076"},{"product_id":"6ag1315-2ah14-7ab0","title":"6AG1315-2AH14-7AB0 Siemens","description":"\u003cdiv class=\"pd-premium\"\u003e\n\u003cdiv class=\"pd-desc-cols\"\u003e\n\u003cdiv class=\"pd-overview\"\u003e\n\u003ch3 class=\"pd-h\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AG1315-2AH14-7AB0 (SIPLUS S7-300 CPU 315-2DP) is a central processing unit module for the SIMATIC S7-300 automation platform. Designed for industrial control systems, it integrates an MPI interface and PROFIBUS DP master\/slave interface. It incorporates an internal 24 V DC supply and 256 KB work memory, with program and data retention via plug-in Micro Memory Card (MMC). It is suited for harsh environments with conformal coating and a -25 °C to +70 °C operating range. This part number appears as a spare variant of CPUs used in discrete and process automation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-suited\"\u003e\n\u003ch3 class=\"pd-h\"\u003eBest Suited For\u003c\/h3\u003e\n\u003cul class=\"pd-checks\"\u003e\n\u003cli\u003eS7-300 control racks in industrial automation\u003c\/li\u003e\n\u003cli\u003eEnvironments requiring conformal-coated spare CPUs\u003c\/li\u003e\n\u003cli\u003eApplications using PROFIBUS DP and MPI communications\u003c\/li\u003e\n\u003cli\u003eLegacy systems maintenance or replacement in harsh conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance\"\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eWork memory\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e256 KB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSupply voltage\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e24 V DC (19.2 … 28.8 V DC)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eInterfaces\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eMPI + PROFIBUS DP (master\/slave)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e-25 °C to +70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eMMC support\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003eYes (up to 8 MB)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"pd-h pd-specs-h\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"pd-spec-grid\"\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eI\/O \u0026amp; Electrical\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSupply voltage (rated)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e24 V DC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eVoltage range\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e19.2 … 28.8 V DC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eRecommended external protection\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e2 A min.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eCurrent consumption (rated)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e850 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eCurrent consumption (no-load), typ.\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e150 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eInrush current, typ.\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e3.5 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eI²t\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1 A²·s\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePower loss, typ.\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e4.5 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eCommunication \u0026amp; Power\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eMPI interface\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003ePROFIBUS DP interface\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eYes (master\/slave)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e-25 °C to +70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eConformal coating\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eWeight\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e0.361 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eDimensions (packaging)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e15 × 13 × 5 cm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eCertifications\u003c\/h4\u003e\n\u003cdiv class=\"pd-badges\"\u003e\n\u003cspan class=\"pd-badge\"\u003eRoHS compliant\u003c\/span\u003e\u003cspan class=\"pd-badge\"\u003eWEEE take-back\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Surplus - Tested (With Warranty)","offer_id":48318273061078,"sku":"6AG1315-2AH14-7AB0","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New \/ Open-Box Surplus","offer_id":48375981179094,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/4912\/0470\/files\/0e5265e3e9f49f4c17536bbd9a1f0d7d.jpg?v=1781497133"},{"product_id":"440r-p226ags-nnr-allen-bradley","title":"440R-P226AGS-NNR Allen-Bradley","description":"\u003cdiv class=\"pd-premium\"\u003e\n\u003cdiv class=\"pd-desc-cols\"\u003e\n\u003cdiv class=\"pd-overview\"\u003e\n\u003ch3 class=\"pd-h\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 440R-P226AGS-NNR is an Allen-Bradley Guardmaster MSR42 Start\/Restart Safety Module. As a base safety relay, it monitors safety devices-such as light curtains or emergency-stop buttons-and provides start and external device monitoring (EDM) logic. The module is DIN-rail mounted in control panels, forming part of safety control circuits in machine guarding, packaging lines, and general industrial automation where monitored start and restart logic is required. 440R-P226AGS-NNR integrates with the MSR relay ecosystem, supporting extension modules and feedback circuits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-suited\"\u003e\n\u003ch3 class=\"pd-h\"\u003eBest Suited For\u003c\/h3\u003e\n\u003cul class=\"pd-checks\"\u003e\n\u003cli\u003eStart\/restart safety logic for light curtain applications\u003c\/li\u003e\n\u003cli\u003eMachine safeguarding with monitored start (category 4 applications)\u003c\/li\u003e\n\u003cli\u003eIntegration with MSR45E extension modules\u003c\/li\u003e\n\u003cli\u003eDIN-rail control panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance\"\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eOutputs\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e2 (NO contacts)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSupply voltage\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e24 V DC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eMounting width\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e22.5 mm module on DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eSwitching current (one contact)\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e8 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-card\"\u003e\n\u003cdiv class=\"pd-glance-label\"\u003eMechanical lifespan\u003c\/div\u003e\n\u003cdiv class=\"pd-glance-value\"\u003e1 × 10⁶ cycles\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"pd-h pd-specs-h\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"pd-spec-grid\"\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eI\/O \u0026amp; Electrical\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSupply voltage\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e24 V DC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eOutputs\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e2 NO contacts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitching current, one contact\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e8 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitching current, ≥2 contacts (1 ext. module)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e6 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitching current, ≥2 contacts (≥2 ext. modules)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e4 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitching voltage, max (2NO)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eAC 250 V; DC 300 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitching voltage, max (3NO or 2NO\/1NC)\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003eAC 120 V; DC 170 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003eCommunication \u0026amp; Power\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitch-on delay\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e\u0026lt; 3 s\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eSwitch-off delay\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e\u0026lt; 40 ms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-card\"\u003e\n\u003ch4 class=\"pd-spec-title\"\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eMounting\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e35 mm DIN rail (module width 22.5 mm)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-row\"\u003e\n\u003cdiv class=\"pd-spec-k\"\u003eMechanical lifespan\u003c\/div\u003e\n\u003cdiv class=\"pd-spec-v\"\u003e1 × 10⁶ cycles\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen Bradley","offers":[{"title":"Surplus - Tested (With Warranty)","offer_id":48317943939286,"sku":"440R-P226AGS-NNR","price":360.0,"currency_code":"USD","in_stock":true},{"title":"New \/ Open-Box Surplus","offer_id":48376135712982,"sku":null,"price":1780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/4912\/0470\/files\/3145a87634df8700c288911618d700a8.jpg?v=1781490837"}],"url":"https:\/\/www.plcdepartment.com\/collections\/siemens-industrial-pcs-6ag.oembed","provider":"PLC Department","version":"1.0","type":"link"}